Ibm System Storage Ds3000 Storage Manager Version 2 Installation
IBM V7. 2. x Supported Hardware List, Device Driver, Firmware and Recommended Software Levels for SAN Volume Controller The documents titled Supported Hardware List and Recommended Software Levels provide the operating systems, Host adapters, SAN fabric elements, RAID controllers and selected other hardware that have been tested or qualified by IBM. This page combines the previously separate Software and Hardware support matrices. For operating systems, we show the latest tested release levels and service packs.
Featured offer. IBM Bluemix. Build, deploy and scale your apps and services, your way. IBM System Storage DS3500 and EXP3500 Storage Subsystem Installation, User's, and Maintenance Guide GA32-0952-06. Warranty Information document that. If you notice problems with the data in the vCG, please let us know. Please note: The team monitoring your feedback cannot respond to the questions about. Subsystem Device Driver Device Specific Module (SDDDSM) installation packages for the Windows Server 2003, 2008,20 operating systems.
Only the listed operating systems are supported. For host adapters, SAN fabric elements and RAID controllers, we list our currently recommended firmware and/or BIOS levels and formally support only the hardware listed. While these levels are not mandatory levels for a customer to be supported by IBM, they are the recommended levels. There may be known operational issues with older firmware and BIOS levels and, in these cases, a customer working with the IBM Support center may be directed to upgrade a component to a recommended level. SVC will support all OS applications at any level that run to the standard block level OS interface.
This includes such applications as Oracle, HP Virtual Connect, etc. Note: * The levels shown in italic text indicate previously recommended levels.* The level shown in bold text indicates the latest recommended level.* EOL - (End of Life): Where interoperability items have gone end of life (out of support) and are no longer supported by the vendor either generally or by extended service contact IBM will continue to support the environment on a best can do basis. Where issues occur which are deemed by IBM support to be directly related to items which are no longer generally supported by the vendor IBM may direct customers to upgrade a component to a recommended level.
Whilst IBM recommends these levels based upon the most recent testing, the following levels were tested against previous versions of SVC and IBM will support the use of these levels with SVC V7. If you have Interoperability requirements which are not listed in this document please contact your IBM Account Representative- -- -- -- -- -- - Previously Supported Levels. SVC Version. Previous Support Levels.
V7.2.x Supported Hardware List, Device Driver, Firmware and Recommended Software Levels for SAN Volume Controller. IBM's technical support resource for all IBM products and services including downloads, fixes, drivers, APARs, product documentation, Redbooks, whitepapers and technotes. The Flex System® Fabric SI4093 System Interconnect Module enables simplified integration of Flex System into your existing networking infrastructure and provides the. Download the free trial version below to get started. Double-click the downloaded file to install the software. Complete Technical Acronyms, Glossary & Definitions for PC, SAN, NAS, QA, Testing, HDTV, Wireless, Linux, Embedded, Networks, Video, Digital, pharma, Unix, Video.
SAN Volume Controller Supported Hardware List, Device Driver, Firmware and Recommended Software Levels V7. SAN Volume Controller Supported Hardware List, Device Driver, Firmware and Recommended Software Levels V6. SAN Volume Controller Supported Hardware List, Device Driver, Firmware and Recommended Software Levels V6. SAN Volume Controller Supported Hardware List, Device Driver, Firmware and Recommended Software Levels V6. SAN Volume Controller Supported Hardware List, Device Driver, Firmware and Recommended Software Levels V6.
Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller. Recommended Software Levels for SAN Volume Controller. Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller.
Recommended Software Levels for SAN Volume Controller. Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller. Recommended Software Levels for SAN Volume Controller. Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller. Recommended Software Levels for SAN Volume Controller. Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller. Recommended Software Levels for SAN Volume Controller.
Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller. Recommended Software Levels for SAN Volume Controller SAN Volume Controller Supported Drive Types. SVC Easy Tier Function Supported Configurations. Tier 0 Storage. Tier 1 Storage.
Notes. Internal SSDs (within SVC nodes)Externally virtualized SAS or NL- SASEasy Tier is not supported in any configuration where SSDs are not exclusively being used as the Tier 0 storage. Externally virtualized SSDs. Externally virtualized SAS or NL- SASSplit Cluster Configuration Documentation. SAN Volume Controller Code Compatibility.
SAN Volume Controller Non Disruptive Volume Move. The following Fibre Channel attached host types are supported for non- disruptively moving a volume between I/O groups (control enclosures). OS Version. NPIV or v. SCSIMultipathing. Clustering. Notes.
AIX7. 1 TL1 with VIOS 2. FP2. 5- SP0. 2NPIVSDDPCM 2. SDDPCM 2. 6. 5. 1. SDDPCM 2. 6. 6. 0.
SDDPCM 2. 6. 7. 0. SDDPCM 2. 6. 8. 0. Non Disruptive Volume Move may leave the same Volume mapped to different hosts in the same host cluster using different SCSI IDs. If the host cluster cannot tolerate this configuration then non disruptive move cannot be used. For Host Clusters which cannot tolerate this condition users should quiesce their hosts, perform the NVDM steps to move the volumes to another IO group, reassign the SCSI IDs manually, then reconfigure and restart the hosts. In SDDPCM 2. 6. 4. SAN Boot is supported.
NPIV is supported. AIX7. 1 TL2 with VIOS 2. SCSISDDPCM 2. 6. 4. SDDPCM 2. 6. 5. 1. SDDPCM 2. 6. 6. 0. SDDPCM 2. 6. 7. 0.
SDDPCM 2. 6. 8. 0. SAN Boot is supported.
SCSI only. NPIV is not supported in this configuration. AIX7. 1 TL2 with VIOS 2. NPIVSDDPCM 2. 6. 4. SDDPCM 2. 6. 5. 1. SDDPCM 2. 6. 6. 0. SDDPCM 2. 6. 7. 0. SDDPCM 2. 6. 8. 0i.
SCSI hosts are not supported. NPIV is supported. SAN Boot Supported, boot path should be updated after NDVMIn NPIV configuration when RAW I/O is running over a disk, some enabled paths of that disk may get failed/invalid during NDVM.
The failed/invalid paths will be recovered automatically by AIX path health check hence application I/O will not be impacted. Disks used by filesystem do not have such issue. SDDPCM 2. 6. 4. 0. SDDPCM 2. 6. 5. 1.
SDDPCM 2. 6. 6. 0. SDDPCM 2. 6. 7. 0. SDDPCM 2. 6. 8. 0v. SCSI only. NPIV is not supported in this configuration. AIX6. 1 TL3 with VIOS 2.
FP- 2. 4 SP- 0. 2v. SCSIAIX7. 1 with VIOS 2. SCSIPower. HA 7. 1 Supported. In NPIV configuration when RAW I/O is running over a disk, some enabled paths of that disk may get failed/invalid during NDVM. The failed/invalid paths will be recovered automatically by AIX path health check hence application I/O will not be impacted. Disks used by filesystem do not have such issue.
SVC host type should be changed to . Bio Rad Cfx Software Free Download. If the host cluster cannot tolerate this configuration then non disruptive move cannot be used. For Host Clusters which cannot tolerate this condition users should quiesce their hosts, perform the NVDM steps to move the volumes to another IO group, reassign the SCSI IDs manually, then reconfigure and restart the hosts.
SCSI hosts are not supported. RHEL6. 1. DMMPi. SCSI hosts are not supported. RHEL6. 2. DMMPSLES1.
SP1. DMMPVMware ESxi. Native. VAAI should be disabled & is not supported using NDVM with SVC. VAAI is also not supported where access of a volume across multiple IOGroups has been allowed. Solaris. 10 u. 10. MPx. IOi. SCSI hosts are not supported. SAN Boot is supported. Solaris 1. 1. 1 SPARCMPx.
IOi. SCSI hosts are not supported. SAN Boot is supported. Hewlett Packard B. Nativei. SCSI hosts are not supported. SAN Boot is supported. For all other host types, I/O should be quiesced when moving a volume. IBM AIX Fibre Channel.
IBM AIX FCo. EHost Bus Adapter. HBA Driver. Multipath Driver. Clustering. SAN Boot. Platform & OS Version. Notes. FC8. 24. 2CNAFC 8. CNADriver included in Technology Level. SDDPCM 2. 6. 4. 0.
SDDPCM 2. 6. 5. 1. SDDPCM 2. 6. 6. 0. SDDPCM 2. 6. 7. 0. SDDPCM 2. 6. 8. 0.
No. No. AIX 5. 3 TL1. EOL: extended service contract only.
AIX 6. 1. Technology Level 1 Technology Level 2 Technology Level 3. Technology Level 4. Technology Level 5. Technology Level 6. Technology Level 7. Technology Level 8.
Technology Level 9. AIX 7. 1. Technology Level 1 Technology Level 2. Technology Level 3. Supported with Cisco Nexus and Brocade 8.
VDX6. 73. 0 FCo. E switches. Please see the switch tables for further information. FC EN0. HFC EN0. JAIX 6. TL9. AIX 7. 1 TL3. IBM AIX i. SCSIHost Bus Adapter. HBA Driver. Multipath Driver.
Clustering. SAN Boot. Platform & OS Version.
Download - Update. Star - Update. Star.
Download the. free trial version below to get started. Double- click the downloaded file.
Update. Star is compatible with Windows platforms. Update. Star has been tested to meet all of the technical requirements to be compatible with. Windows 1. 0, 8. 1, Windows 8, Windows 7, Windows Vista, Windows Server 2.
Windows. XP, 3. 2 bit and 6. Simply double- click the downloaded file to install it. Update. Star Free and Update. Star Premium come with the same installer.
Update. Star includes support for many languages such as English, German, French, Italian, Hungarian, Russian and many more. You can choose your language settings from within the program.